Follow
Mehenna Arib
Mehenna Arib
King Faisal specialist Hospital and Research Centre
Verified email at kfshrc.edu.sa
Title
Cited by
Cited by
Year
Radiation shielding properties of transparent erbium zinc tellurite glass system determined at medical diagnostic energies
SA Tijani, SM Kamal, Y Al-Hadeethi, M Arib, MA Hussein, S Wageh, ...
Journal of Alloys and Compounds 741, 293-299, 2018
1322018
A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions
J Iżewska, D Georg, P Bera, D Thwaites, M Arib, M Saravi, K Sergieva, ...
Radiotherapy and oncology 84 (1), 67-74, 2007
792007
A multinational audit of small field output factors calculated by treatment planning systems used in radiotherapy
W Lechner, P Wesolowska, G Azangwe, M Arib, VGL Alves, L Suming, ...
Physics and Imaging in Radiation Oncology 5, 58-63, 2018
522018
Testing the methodology for dosimetry audit of heterogeneity corrections and small MLC-shaped fields: results of IAEA multi-center studies
J Izewska, P Wesolowska, G Azangwe, DS Followill, DI Thwaites, M Arib, ...
Acta Oncologica 55 (7), 909-916, 2016
252016
Intercomparison 2013 on measurements of the personal dose equivalent Hp(10) in photon fields in the African region
M Arib, A Herrati, F Dari, J Ma, Z Lounis-Mokrani
Radiation Protection Dosimetry 163 (3), 276-283, 2015
162015
Establishment of ISO 4037-1 X-ray narrow-spectrum series at SSDL of Algiers
A Herrati, M Arib, T Sidahmed, K Khalal-Kouache
Radiation protection dosimetry 174 (1), 35-52, 2017
152017
Study of the influence of phantom material and size on the calibration of ionization chambers in terms of absorbed dose to water
M Arib, T Medjadj, Y Boudouma
Journal of Applied Clinical Medical Physics 7 (3), 55-64, 2006
112006
Optimum parameters of TLD100 powder used for radiotherapy beams calibration check
M Arib, A Yaich, A Messadi, F Dari
Medical Dosimetry 31 (3), 184-189, 2006
102006
Guidelines for the preparation of a quality manual for external audit groups on dosimetry in radiotherapy
J Izewska, M Arib, M Saravi
82002
A multinational audit of small field output factors calculated by treatment planning systems used in radiotherapy. Phys Imaging Radiat Oncol. 2018; 5: 58–63
W Lechner, P Wesolowska, G Azangwe, M Arib, VGL Alves, L Suming, ...
7
Initial Experiences in Testing The IAEA/AAPM Code of Practice on Small Field Dosimetry
W Lechner, M Arib, P Ballesteros‐Zebadúa, K Christaki, P Francescon, ...
International Conference on Advances in Radiation Oncology (ICARO-2), Vienna …, 2017
42017
A multi‐institutional evaluation of small field output factor determination following the recommendations of IAEA/AAPM TRS‐483
W Lechner, R Alfonso, M Arib, MS Huq, A Ismail, R Kinhikar, ...
Medical Physics 49 (8), 5537-5550, 2022
32022
A quality assurance programme in dosimetry for Algeria: from simple to complex
M Arib, S Khoudri, MS Bali, A Yennoune, A Toutaoui, F Dari, A Yaiche, ...
32010
A comprehensive quality assurance Program for radiotherapy using TLD: The Algerian Experience
M Arib, T Medjadj, F Dari, MS Bali, S Khoudri, A Yennoune, B Hattali
World Congress on Medical Physics and Biomedical Engineering, September 7-12 …, 2009
22009
Calibration of plane parallel ionization chambers: a new service for secondary standard dosimetry laboratories?
M Arib, H Chekerker, S Benmokhtar, A Meghzifene
Medical Dosimetry 26 (4), 301-304, 2001
22001
Small field output factor measurement and verification for CyberKnife robotic radiotherapy and radiosurgery system using 3D polymer gel, ionization chamber, diode, diamond and …
MA Al Kafi, M Arib, A Al Moussa, F Alzorkany, M Shehadeh, MFM Yusof, ...
Applied Radiation and Isotopes 192, 110576, 2023
12023
Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications
I Algain, M Arib, SAF Al-Said, H Donya
Sensors 23 (2), 1011, 2023
12023
IAEA-SSDL bilateral comparisons for diagnostic level air kerma measurement standards
I Csete, P Toroi, A Steuer, C Hourdakis, F Gabris, S Jozela, A Kosunen, ...
Physica Medica 47, 9-15, 2018
12018
Effect of background and transport dose on the results of the personal dose equivalent Hp(10) measurements in photon fields obtained during the intercomparison …
M Arib, A Herrati, F Dari, Z Lounis-Mokrani
Radiation protection dosimetry 167 (4), 399-404, 2015
12015
Characterization of a PMMA embedded extrapolation chamber in 60Co gamma beams
M Arib, AK Mostefai, T Medjadj, M Tilmati, Y Boudouma
World Congress on Medical Physics and Biomedical Engineering, September 7-12 …, 2009
12009
The system can't perform the operation now. Try again later.
Articles 1–20