Assessment of CFD performance in simulations of an idealized medical device: results of FDA’s first computational interlaboratory study SFC Stewart, EG Paterson, GW Burgreen, P Hariharan, M Giarra, ... Cardiovascular Engineering and Technology 3, 139-160, 2012 | 209 | 2012 |
FDA Benchmark Medical Device Flow Models for CFD Validation RA Malinauskas, P Hariharan, SW Day, LH Herbertson, M Buesen, ... ASAIO Journal 63 (2), 150-160, 2017 | 154 | 2017 |
Multilaboratory particle image velocimetry analysis of the FDA benchmark nozzle model to support validation of computational fluid dynamics simulations P Hariharan, M Giarra, V Reddy, SW Day, KB Manning, S Deutsch, ... Journal of biomechanical engineering 133 (4), 2011 | 151 | 2011 |
Peristaltic transport of non-Newtonian fluid in a diverging tube with different wave forms P Hariharan, V Seshadri, RK Banerjee Mathematical and Computer Modelling 48 (7-8), 998-1017, 2008 | 115 | 2008 |
HIFU procedures at moderate intensities—effect of large blood vessels P Hariharan, MR Myers, RK Banerjee Physics in medicine and biology 52, 3493, 2007 | 104 | 2007 |
Results of FDA’s first interlaboratory computational study of a nozzle with a sudden contraction and conical diffuser SFC Stewart, P Hariharan, EG Paterson, GW Burgreen, V Reddy, SW Day, ... Cardiovascular Engineering and Technology 4, 374-391, 2013 | 71 | 2013 |
Modeling the Effectiveness of Respiratory Protective Devices in Reducing Influenza Outbreak J Yan, S Guha, P Hariharan, M Myers Risk Analysis 39 (3), 647-661, 2019 | 66 | 2019 |
Characterization of high intensity focused ultrasound transducers using acoustic streaming P Hariharan, MR Myers, RA Robinson, SH Maruvada, J Sliwa, ... The Journal of the Acoustical Society of America 123 (3), 1706-1719, 2008 | 52 | 2008 |
Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels S Dasgupta, RK Banerjee, P Hariharan, MR Myers Ultrasonics 51 (2), 171-180, 2011 | 50 | 2011 |
Assessing Computational Model Credibility Using a Risk-Based Framework: Application to Hemolysis in Centrifugal Blood Pumps TM Morrison, P Hariharan, CM Funkhouser, P Afshari, M Goodin, ... Asaio Journal 65 (4), 349, 2019 | 47 | 2019 |
Enhancement of ICRP's Lung Deposition Model for Pathogenic Bioaerosols S Guha, P Hariharan, MR Myers Aerosol Science and Technology 48 (12), 1226-1235, 2014 | 47 | 2014 |
Inter-laboratory characterization of the velocity field in the FDA blood pump model using particle image velocimetry (PIV) P Hariharan, KI Aycock, M Buesen, SW Day, BC Good, LH Herbertson, ... Cardiovascular engineering and technology 9, 623-640, 2018 | 40 | 2018 |
Use of the FDA nozzle model to illustrate validation techniques in computational fluid dynamics (CFD) simulations. P Hariharan, GA D'Souza, M Horner, TM Morrison, RA Malinauskas, ... PloS one 12 (6), e0178749, 2017 | 39 | 2017 |
Verification Benchmarks to Assess the Implementation of Computational Fluid Dynamics Based Hemolysis Prediction Models P Hariharan, G D’Souza, M Horner, RA Malinauskas, MR Myers Journal of biomechanical engineering 137 (9), 094501, 2015 | 38 | 2015 |
Particle image velocimetry measurements in an anatomical vascular model fabricated using inkjet 3D printing KI Aycock, P Hariharan, BA Craven Experiments in Fluids 58, 1-8, 2017 | 33 | 2017 |
Quantification of leakage of sub-micron aerosols through surgical masks and facemasks for pediatric use S Guha, B McCaffrey, P Hariharan, MR Myers Journal of Occupational and Environmental Hygiene 14 (3), 214-223, 2017 | 30 | 2017 |
Time-resolved particle image velocimetry measurements with wall shear stress and uncertainty quantification for the FDA nozzle model JS Raben, P Hariharan, R Robinson, R Malinauskas, PP Vlachos Cardiovascular engineering and technology 7, 7-22, 2016 | 24 | 2016 |
Time-resolved particle image velocimetry measurements with wall shear stress and uncertainty quantification for the FDA nozzle model JS Raben, P Hariharan, R Robinson, R Malinauskas, PP Vlachos Cardiovascular engineering and technology 7, 7-22, 2016 | 24 | 2016 |
Clinical evaluation of non-contact infrared thermometers SJL Sullivan, JE Rinaldi, P Hariharan, JP Casamento, S Baek, N Seay, ... Scientific reports 11 (1), 1-10, 2021 | 23 | 2021 |
HIFU lesion volume as a function of sonication time, as determined by MRI, histology, and computations S Dasgupta, J Wansapura, P Hariharan, R Pratt, D Witte, MR Myers, ... | 23 | 2010 |