Vicente Climente-Alarcon
Vicente Climente-Alarcon
Postdoctoral researcher, University of Cambridge, UK
Verified email at cam.ac.uk
TitleCited byYear
Induction motor diagnosis based on a transient current analytic wavelet transform via frequency B-splines
J Pons-Llinares, JA Antonino-Daviu, M Riera-Guasp, M Pineda-Sanchez, ...
IEEE Transactions on Industrial Electronics 58 (5), 1530-1544, 2010
1252010
Induction motor diagnosis by advanced notch FIR filters and the Wigner–Ville distribution
V Climente-Alarcon, JA Antonino-Daviu, M Riera-Guasp, M Vlcek
IEEE Transactions on Industrial Electronics 61 (8), 4217-4227, 2013
772013
Vibration transient detection of broken rotor bars by PSH sidebands
V Climente-Alarcon, JA Antonino-Daviu, F Vedreño-Santos, ...
IEEE Transactions on Industry Applications 49 (6), 2576-2582, 2013
702013
Application of the Teager–Kaiser energy operator to the fault diagnosis of induction motors
M Pineda-Sanchez, R Puche-Panadero, M Riera-Guasp, J Perez-Cruz, ...
IEEE Transactions on energy conversion 28 (4), 1036-1044, 2013
682013
Application of the Wigner–Ville distribution for the detection of rotor asymmetries and eccentricity through high-order harmonics
V Climente-Alarcon, JA Antonino-Daviu, M Riera-Guasp, ...
Electric Power Systems Research 91, 28-36, 2012
602012
Principal Component Analysis of the start-up transient and Hidden Markov Modeling for broken rotor bar fault diagnosis in asynchronous machines
G Georgoulas, MO Mustafa, IP Tsoumas, JA Antonino-Daviu, ...
Expert Systems with Applications 40 (17), 7024-7033, 2013
562013
Automatic pattern identification based on the complex empirical mode decomposition of the startup current for the diagnosis of rotor asymmetries in asynchronous machines
G Georgoulas, IP Tsoumas, JA Antonino-Daviu, V Climente-Alarcón, ...
IEEE Transactions on Industrial Electronics 61 (9), 4937-4946, 2013
562013
Combination of noninvasive approaches for general assessment of induction motors
MJ Picazo-Rodenas, J Antonino-Daviu, V Climente-Alarcon, ...
IEEE Transactions on Industry Applications 51 (3), 2172-2180, 2014
532014
A symbolic representation approach for the diagnosis of broken rotor bars in induction motors
P Karvelis, G Georgoulas, IP Tsoumas, JA Antonino-Daviu, ...
IEEE Transactions on Industrial Informatics 11 (5), 1028-1037, 2015
452015
Rotor-bar breakage mechanism and prognosis in an induction motor
V Climente-Alarcon, JA Antonino-Daviu, EG Strangas, M Riera-Guasp
IEEE Transactions on Industrial Electronics 62 (3), 1814-1825, 2014
432014
Time-frequency vibration analysis for the detection of motor damages caused by bearing currents
A Prudhom, J Antonino-Daviu, H Razik, V Climente-Alarcon
Mechanical Systems and Signal Processing 84, 747-762, 2017
352017
Transient-based rotor cage assessment in induction motors operating with soft starters
JA Corral-Hernandez, J Antonino-Daviu, J Pons-Llinares, ...
IEEE Transactions on Industry Applications 51 (5), 3734-3742, 2015
282015
Transient tracking of low and high-order eccentricity-related components in induction motors via TFD tools
V Climente-Alarcon, J Antonino-Daviu, M Riera-Guasp, J Pons-Llinares, ...
Mechanical Systems and Signal Processing 25 (2), 667-679, 2011
272011
Electric machines diagnosis techniques via transient current analysis
J Pons-Llinares, V Climente-Alarcón, F Vedreño-Santos, ...
IECON 2012-38th Annual Conference on IEEE Industrial Electronics Society …, 2012
262012
Diagnosis of induction motors under varying speed operation by principal slot harmonic tracking
V Climente-Alarcon, JA Antonino-Daviu, A Haavisto, A Arkkio
IEEE Transactions on Industry Applications 51 (5), 3591-3599, 2015
232015
An automated thermographic image segmentation method for induction motor fault diagnosis
P Karvelis, G Georgoulas, CD Stylios, IP Tsoumas, JA Antonino-Daviu, ...
IECON 2014-40th Annual Conference of the IEEE Industrial Electronics Society …, 2014
232014
Particle filter-based estimation of instantaneous frequency for the diagnosis of electrical asymmetries in induction machines
V Climente-Alarcon, JA Antonino-Daviu, A Haavisto, A Arkkio
IEEE Transactions on Instrumentation and Measurement 63 (10), 2454-2463, 2014
222014
Diagnosis of induction machines under non-stationary conditions: Concepts and tools
M Riera-Guasp, J Pons-Llinares, V Climente-Alarcon, F Vedreño-Santos, ...
2013 IEEE Workshop on Electrical Machines Design, Control and Diagnosis …, 2013
192013
Evaluation of the detectability of electromechanical faults in induction motors via transient analysis of the stray flux
JA Ramirez-Nunez, JA Antonino-Daviu, V Climente-Alarcón, ...
IEEE Transactions on Industry Applications 54 (5), 4324-4332, 2018
182018
The use of a multilabel classification framework for the detection of broken bars and mixed eccentricity faults based on the start-up transient
G Georgoulas, V Climente-Alarcon, JA Antonino-Daviu, IP Tsoumas, ...
IEEE Transactions on Industrial Informatics 13 (2), 625-634, 2016
182016
The system can't perform the operation now. Try again later.
Articles 1–20