Följ
Audrey K Nebergall
Audrey K Nebergall
Johns Hopkins University School of Medicine
Verifierad e-postadress på jhmi.edu
Titel
Citeras av
Citeras av
År
Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases
A Nebergall, C Bragdon, A Antonellis, J Kärrholm, R Brånemark, ...
Acta orthopaedica 83 (2), 121-128, 2012
1472012
Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis
AK Nebergall, ME Greene, MB Laursen, PT Nielsen, H Malchau, ...
The bone & joint journal 99 (5), 577-584, 2017
652017
Three year RSA evaluation of vitamin E diffused highly cross-linked polyethylene liners and cup stability
NH Sillesen, ME Greene, AK Nebergall, PT Nielsen, MB Laursen, ...
The Journal of arthroplasty 30 (7), 1260-1264, 2015
422015
Are there gender-based differences in language in letters of recommendation to an orthopaedic surgery residency program?
AN Kobayashi, RS Sterling, SA Tackett, BW Chee, DM Laporte, ...
Clinical Orthopaedics and Related Research® 478 (7), 1400-1408, 2020
392020
Precision of radiostereometric analysis (RSA) of acetabular cup stability and polyethylene wear improved by adding tantalum beads to the liner
AK Nebergall, K Rader, H Palm, H Malchau, ME Greene
Acta orthopaedica 86 (5), 563-568, 2015
392015
Five-year experience of vitamin e–diffused highly cross-linked polyethylene wear in total hip arthroplasty assessed by radiostereometric analysis
AK Nebergall, A Troelsen, HE Rubash, H Malchau, O Rolfson, ME Greene
The Journal of arthroplasty 31 (6), 1251-1255, 2016
362016
Medial overhang of the tibial component is associated with higher risk of inferior knee injury and osteoarthritis outcome score pain after knee replacement
CS Nielsen, A Nebergall, J Huddleston, T Kallemose, H Malchau, ...
The Journal of arthroplasty 33 (5), 1394-1398, 2018
342018
Thirteen-year evaluation of highly cross-linked polyethylene articulating with either 28-mm or 36-mm femoral heads using radiostereometric analysis and computerized tomography
AK Nebergall, ME Greene, H Rubash, H Malchau, A Troelsen, O Rolfson
The Journal of arthroplasty 31 (9), 269-276, 2016
292016
3-year follow-up of a long-term registry-based multicentre study on vitamin E diffused polyethylene in total hip replacement
NH Sillesen, ME Greene, AK Nebergall, JI Huddleston, R Emerson, ...
Hip international 26 (1), 97-103, 2016
252016
Stable fixation of a cementless, proximally coated, double wedged, double tapered femoral stem in total hip arthroplasty: a 5-year radiostereometric analysis
AK Nebergall, O Rolfson, HE Rubash, H Malchau, A Troelsen, ME Greene
The Journal of arthroplasty 31 (6), 1267-1274, 2016
242016
Analysis of dual mobility liner rim damage using retrieved components and cadaver models
AK Nebergall, AA Freiberg, ME Greene, H Malchau, O Muratoglu, ...
The Journal of Arthroplasty 31 (7), 1595-1602, 2016
192016
Radiographic and clinical outcomes of porous titanium-coated and plasma-sprayed acetabular shells: a five-year prospective multicenter study
V Lindgren, VP Galea, A Nebergall, ME Greene, O Rolfson, H Malchau, ...
JBJS 100 (19), 1673-1681, 2018
182018
Registries collecting level-I through IV Data: institutional and multicenter use: AAOS exhibit selection
VJ Hansen, ME Greene, MA Bragdon, AK Nebergall, CJ Barr, ...
JBJS 96 (18), e160, 2014
182014
Radiostereometric and radiographic analysis of glenoid component motion after total shoulder arthroplasty
JJ Streit, Y Shishani, ME Greene, AK Nebergall, JP Wanner, CR Bragdon, ...
Orthopedics 38 (10), e891-e897, 2015
152015
RSA evaluation of vitamin E diffused highly crosslinked polyethylene and acetabular and femoral component stability
M Greene, N Sillesen, A Nebergall, H Rubash, YM Kwon, C Bragdon, ...
Annual meeting of the American academy of orthopaedic surgeons. Chicago …, 2013
72013
New cementless fixation in hip arthroplasty: a radiostereometric analysis
A Matejcic, D Vidovic, A Nebergall, M Greene, S Bresina, S Tepic, ...
Hip International 25 (5), 477-483, 2015
52015
Five-year experience of vitamin E stabilised, irradiated ultra-high molecular weight polyethylene wear and stability of regenerex acetabular shells and femoral components using RSA
A Nebergall, M Greene, N Sillesen, HE Rubash, YM Kwon, H Malchau
Orthopaedic Proceedings 98 (SUPP_3), 82-82, 2016
42016
FIVE-YEAR RSA EVALUATION OF VITAMIN E DIFFUSED HIGHLY CROSS-LINKED POLYETHYLENE WEAR AND STABILITY OF FEMORAL STEMS
CR Bragdon, C Barr, A Nebergall, O Rolfson, A Troelsen, HE Rubash, ...
Orthopaedic Proceedings 99 (SUPP_3), 34-34, 2017
2017
SOFT-TISSUE IMPINGEMENT IN DUAL MOBILITY COMPONENTS: A PROPOSED MECHANISM OF INTRAPROSTHETIC DISLOCATION USING CADAVER MODELS AND RETRIEVALS
A Nebergall, A Freiberg, M Greene, H Malchau, O Muratoglu, S Rowell, ...
Orthopaedic Proceedings 98 (SUPP_9), 80-80, 2016
2016
Vitamin E Diffused Highly Cross-Linked Polyethylene In Total Hip Arthroplasty At 5 Years: A Randomized Controlled Trial Using Radiostereometric Analysis
A Nebergall, ME Greene, MB Laursen, PT Nielsen, H Malchau, ...
2016
Systemet kan inte utföra åtgärden just nu. Försök igen senare.
Artiklar 1–20