Performance analysis of new liquid cooling topology and its impact on data centres M Hnayno, A Chehade, H Klaba, H Bauduin, G Polidori, C Maalouf Applied Thermal Engineering 213, 118733, 2022 | 15 | 2022 |
Experimental investigation of a data-centre cooling system using a new single-phase immersion/liquid technique M Hnayno, A Chehade, H Klaba, G Polidori, C Maalouf Case Studies in Thermal Engineering 45, 102925, 2023 | 13 | 2023 |
Hybrid immersion cooling system for rack-mounted electronic assemblies M Hnayno, A Chehade, H Klaba US Patent 11,924,998, 2024 | 1 | 2024 |
Experimental investigation of an autonomous liquid-cooled uninterruptible power supply (UPS) M Hnayno, A Chehade, H Klaba, H Bauduin, G Polidori, C Maalouf Energy Reports 9, 5775-5787, 2023 | 1 | 2023 |
HERMETIC SEALED ELECTRONIC ASSEMBLY FOR NON DIELECTRIC IMMERSION COOLING SYSTEM A Chehade, M Hnayno US Patent App. 18/236,509, 2024 | | 2024 |
HYBRID LIQUID COOLING ARRANGEMENT FOR AUTONOMOUS AND IMMERSION COOLED RACKS M Hnayno, A Chehade, T Vuillier US Patent App. 18/236,498, 2024 | | 2024 |
COOLING ASSEMBLY AND METHOD FOR COOLING A PLURALITY OF HEAT-GENERATING COMPONENTS M Hnayno, A Chehade, H Klaba US Patent App. 18/236,033, 2024 | | 2024 |
Detection and deflection of fluid leakages in immersion cooling systems M HNAYNO, A CHEHADE, H Klaba US Patent App. 18/233,922, 2024 | | 2024 |
Immersion-cooled electronic device and cooling monitoring system for immersion-cooled electronic device A CHEHADE, M HNAYNO, H Klaba US Patent App. 18/232,865, 2024 | | 2024 |
Immersion cooling container A Chehade, M Hnayno US Patent App. 18/373,567, 2024 | | 2024 |
Heat exchanger system having a mesh panel A Chehade, M Hnayno, L Genelle US Patent 11,815,319, 2023 | | 2023 |
Experimental investigation of an optimized indirect free cooling system including a dry cooler equipped with evaporative cooling pads for data center M Hnayno, A Chehade, H Klaba, G Polidori, C Maalouf Energy Reports 9, 460-469, 2023 | | 2023 |
Cooling arrangement having a closed loop, a semi-open loop and at least one fan M Hnayno, H Bauduin, A Chakir, A Chehade US Patent 11,768,035, 2023 | | 2023 |
Optimisation des performances énergétiques des centres de données: du composant au bâtiment M Hnayno Reims, 2023 | | 2023 |
Rack assembly for a data center and method for controlling cooling fluid in a cooling loop of the rack assembly A Chehade, M Hnayno, H Bauduin, H Klaba US Patent App. 17/889,972, 2023 | | 2023 |
Cooling device A Chehade, M Hnayno, H Klaba US Patent App. 17/698,480, 2022 | | 2022 |
Heat sink having non-straight fins for orienting a flow of an immersive cooling fluid A Chehade, M Hnayno, H Bauduin US Patent App. 17/690,833, 2022 | | 2022 |
Energy Reports M Hnayno, A Chehade, H Klaba, G Polidori, C Maalouf | | |