John Adamovics
John Adamovics
Verified email at rider.edu
Title
Cited by
Cited by
Year
Characterisation of PRESAGE™: A new 3-D radiochromic solid polymer dosemeter for ionising radiation
J Adamovics, MJ Maryanski
Radiation protection dosimetry 120 (1-4), 107-112, 2006
2172006
Characterization of a new radiochromic three‐dimensional dosimeter
PY Guo, JA Adamovics, M Oldham
Medical physics 33 (5), 1338-1345, 2006
1752006
Chromatographic analysis of pharmaceuticals
JA Adamovics
Routledge, 2017
1672017
A comprehensive evaluation of the PRESAGE/optical‐CT 3D dosimetry system
HS Sakhalkar, J Adamovics, G Ibbott, M Oldham
Medical Physics 36 (1), 71-82, 2009
1322009
A practical three‐dimensional dosimetry system for radiation therapy
P Guo, J Adamovics, M Oldham
Medical physics 33 (10), 3962-3972, 2006
1202006
Radiological properties of the PRESAGE and PAGAT polymer dosimeters
S Brown, A Venning, Y De Deene, P Vial, L Oliver, J Adamovics, ...
Applied Radiation and Isotopes 66 (12), 1970-1974, 2008
1062008
Commissioning and benchmarking a 3D dosimetry system for clinical use
A Thomas, J Newton, J Adamovics, M Oldham
Medical physics 38 (8), 4846-4857, 2011
1052011
Secondary chemical equilibria in high-performance liquid chromatography
BL Karger, JN LePage, N Tanaka
High-Performance Liquid Chromatography, 113-206, 1980
99*1980
Three-dimensional dosimeter for penetrating radiation and method of use
JA Adamovics
US Patent 7,098,463, 2006
922006
Investigation of radiological properties and water equivalency of PRESAGE® dosimeters
T Gorjiara, R Hill, Z Kuncic, J Adamovics, S Bosi, JH Kim, C Baldock
Medical physics 38 (4), 2265-2274, 2011
892011
An investigation of the accuracy of an IMRT dose distribution using two‐and three‐dimensional dosimetry techniques
M Oldham, H Sakhalkar, P Guo, J Adamovics
Medical physics 35 (5), 2072-2080, 2008
872008
Commissioning a small‐field biological irradiator using point, 2D, and 3D dosimetry techniques
J Newton, M Oldham, A Thomas, Y Li, J Adamovics, DG Kirsch, S Das
Medical physics 38 (12), 6754-6762, 2011
812011
A new approach to radiochromic three-dimensional dosimetry-polyurethane
J Adamovics, MJ Maryanski
Journal of Physics: Conference Series 3 (1), 020, 2004
712004
Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE®/optical-CT 3D dosimetry system
C Clift, A Thomas, J Adamovics, Z Chang, I Das, M Oldham
Physics in Medicine & Biology 55 (5), 1279, 2010
652010
Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using Presage/optical‐CT
H Sakhalkar, D Sterling, J Adamovics, G Ibbott, M Oldham
Medical physics 36 (7), 3371-3377, 2009
642009
Prodrug analogs of the antitumor alkaloid camptothecin
JA Adamovics, CR Hutchinson
Journal of medicinal chemistry 22 (3), 310-314, 1979
581979
New 3D radiochromic solid polymer dosimeter from leuco dyes and a transparent polymeric matrix
J Adamovics, M Maryanski
Medical Physics 30 (6), 2003
532003
A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation
M Oldham, A Thomas, J O’Daniel, T Juang, G Ibbott, J Adamovics, ...
International Journal of Radiation Oncology* Biology* Physics 84 (2), 540-546, 2012
522012
On the need for comprehensive validation of deformable image registration, investigated with a novel 3-dimensional deformable dosimeter
T Juang, S Das, J Adamovics, R Benning, M Oldham
International Journal of Radiation Oncology* Biology* Physics 87 (2), 414-421, 2013
512013
Ferulates from cork layers of Solanum tuberosum and Pseudotsuga menziesii
JA Adamovics, G Johnson, FR Stermitz
Phytochemistry, 1977
461977
The system can't perform the operation now. Try again later.
Articles 1–20