Follow
Erik Groot Jebbink
Title
Cited by
Cited by
Year
Detection of ‘best’positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial
P Blankman, D Hasan, GJ Erik, D Gommers
Critical care 18, 1-10, 2014
1062014
Three-year outcome of the covered endovascular reconstruction of the aortic bifurcation technique for aortoiliac occlusive disease
K Taeymans, EG Jebbink, S Holewijn, JM Martens, M Versluis, ...
Journal of vascular surgery 67 (5), 1438-1447, 2018
622018
Geometrical consequences of kissing stents and the Covered Endovascular Reconstruction of the Aortic Bifurcation configuration in an in vitro model for endovascular …
EG Jebbink, FAB Grimme, PCJM Goverde, JA van Oostayen, CH Slump, ...
Journal of vascular surgery 61 (5), 1306-1311, 2015
622015
Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease
EG Jebbink, V Mathai, JT Boersen, C Sun, CH Slump, PCJM Goverde, ...
Journal of vascular surgery 66 (1), 251-260. e1, 2017
452017
Systematic review of results of kissing stents in the treatment of aortoiliac occlusive disease
EG Jebbink, S Holewijn, CH Slump, JW Lardenoije, MMPJ Reijnen
Annals of vascular surgery 42, 328-336, 2017
332017
Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model
JT Boersen, EG Jebbink, M Versluis, CH Slump, DN Ku, JPPM de Vries, ...
Journal of vascular surgery 66 (6), 1844-1853, 2017
292017
High-frame-rate contrast-enhanced US particle image velocimetry in the abdominal aorta: first human results
S Engelhard, J Voorneveld, HJ Vos, JJM Westenberg, FJH Gijsen, ...
Radiology 289 (1), 119-125, 2018
252018
Meta-analysis of individual patient data after kissing stent treatment for aortoiliac occlusive disease
E Groot Jebbink, S Holewijn, M Versluis, F Grimme, JW Hinnen, S Sixt, ...
Journal of Endovascular Therapy 26 (1), 31-40, 2019
232019
High-frame-rate contrast-enhanced ultrasound for velocimetry in the human abdominal aorta
J Voorneveld, S Engelhard, HJ Vos, MMPJ Reijnen, F Gijsen, M Versluis, ...
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 65 …, 2018
222018
In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
E Groot Jebbink, TG Ter Mors, CH Slump, RH Geelkerken, S Holewijn, ...
Vascular 25 (6), 635-641, 2017
192017
Benchtop quantification of gutter formation and compression of chimney stent grafts in relation to renal flow in chimney endovascular aneurysm repair and endovascular aneurysm …
JT Boersen, EJ Donselaar, EG Jebbink, R Starreveld, SP Overeem, ...
Journal of vascular surgery 66 (5), 1565-1573. e1, 2017
172017
Classification of gutter type in parallel stenting during endovascular aortic aneurysm repair
SP Overeem, JT Boersen, RCL Schuurmann, EG Jebbink, CH Slump, ...
Journal of vascular surgery 66 (2), 594-599, 2017
172017
Native blood speckle vs ultrasound contrast agent for particle image velocimetry with ultrafast ultrasound-in vitro experiments
J Voorneveld, P Kruizinga, HJ Vos, FJH Gijsen, EG Jebbink, ...
2016 IEEE International Ultrasonics Symposium (IUS), 1-4, 2016
172016
In vitro quantification of gutter formation and chimney graft compression in chimney EVAR stent-graft configurations using electrocardiography-gated computed tomography
SP Overeem, EJ Donselaar, JT Boersen, E Groot Jebbink, CH Slump, ...
Journal of Endovascular Therapy 25 (3), 387-394, 2018
162018
Effect of abdominal aortic endoprostheses on arterial pulse wave velocity in an in vitro abdominal aortic flow model
K Van Noort, S Holewijn, RCL Schuurmann, JT Boersen, SP Overeem, ...
Physiological measurement 39 (10), 104001, 2018
132018
Contrast-enhanced high-frame-rate ultrasound imaging of flow patterns in cardiac chambers and deep vessels
HJ Vos, JD Voorneveld, EG Jebbink, CH Leow, L Nie, AE van den Bosch, ...
Ultrasound in Medicine & Biology 46 (11), 2875-2890, 2020
112020
Partial renal coverage in endovascular aneurysm repair causes unfavorable renal flow patterns in an infrarenal aneurysm model
L van de Velde, EJ Donselaar, EG Jebbink, JT Boersen, GPR Lajoinie, ...
Journal of vascular surgery 67 (5), 1585-1594, 2018
112018
Validation of the Simbionix PROcedure Rehearsal Studio sizing module: A comparison of software for endovascular aneurysm repair sizing and planning
JF Velu, E Groot Jebbink, JPPM de Vries, CH Slump, RH Geelkerken
Vascular 25 (1), 80-85, 2017
112017
A novel roller pump for physiological flow
A Chong, Z Sun, L van de Velde, S Jansen, M Versluis, MMPJ Reijnen, ...
Artificial organs 44 (8), 818-826, 2020
102020
Innovation in aortoiliac stenting: an in vitro comparison
EG Jebbink, P Goverde, JA van Oostayen, M Reijnen, CH Slump
Medical Imaging 2014: Image-Guided Procedures, Robotic Interventions, and …, 2014
82014
The system can't perform the operation now. Try again later.
Articles 1–20