Follow
Louis Archambault
Title
Cited by
Cited by
Year
Validation of GEANT4, an object‐oriented Monte Carlo toolkit, for simulations in medical physics
JF Carrier, L Archambault, L Beaulieu, R Roy
Medical physics 31 (3), 484-492, 2004
2282004
Measurement accuracy and Cerenkov removal for high performance, high spatial resolution scintillation dosimetry
L Archambault, AS Beddar, L Gingras, R Roy, L Beaulieu
Medical physics 33 (1), 128-135, 2006
2082006
Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov …
M Guillot, L Gingras, L Archambault, S Beddar, L Beaulieu
Medical physics 38 (4), 2140-2150, 2011
1672011
Water‐equivalent dosimeter array for small‐field external beam radiotherapy
L Archambault, AS Beddar, L Gingras, F Lacroix, R Roy, L Beaulieu
Medical physics 34 (5), 1583-1592, 2007
1322007
Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators
L Archambault, J Arsenault, L Gingras, A Sam Beddar, R Roy, L Beaulieu
Medical physics 32 (7Part1), 2271-2278, 2005
1282005
Toward a real-time in vivo dosimetry system using plastic scintillation detectors
L Archambault, TM Briere, F Pönisch, L Beaulieu, DA Kuban, A Lee, ...
International Journal of Radiation Oncology* Biology* Physics 78 (1), 280-287, 2010
1182010
On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry
F Therriault-Proulx, L Beaulieu, L Archambault, S Beddar
Physics in Medicine & Biology 58 (7), 2073, 2013
1152013
A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife
J Morin, D Béliveau‐Nadeau, E Chung, J Seuntjens, D Thériault, ...
Medical physics 40 (1), 011719, 2013
1152013
Exploration of the potential of liquid scintillators for real‐time 3D dosimetry of intensity modulated proton beams
S Beddar, L Archambault, N Sahoo, F Poenisch, GT Chen, MT Gillin, ...
Medical Physics 36 (5), 1736-1743, 2009
962009
Clinical prototype of a plastic water‐equivalent scintillating fiber dosimeter array for QA applications a
F Lacroix, L Archambault, L Gingras, M Guillot, AS Beddar, L Beaulieu
Medical physics 35 (8), 3682-3690, 2008
952008
Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance
JC Gagnon, D Thériault, M Guillot, L Archambault, S Beddar, L Gingras, ...
Medical physics 39 (1), 429-436, 2012
882012
Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors
DM Klein, RC Tailor, L Archambault, L Wang, F Therriault‐Proulx, ...
Medical physics 37 (10), 5541-5549, 2010
842010
Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams
LLW Wang, LA Perles, L Archambault, N Sahoo, D Mirkovic, S Beddar
Physics in Medicine & Biology 57 (23), 7767, 2012
802012
A new water‐equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy
M Guillot, L Beaulieu, L Archambault, S Beddar, L Gingras
Medical physics 38 (12), 6763-6774, 2011
752011
Current status of scintillation dosimetry for megavoltage beams
L Beaulieu, M Goulet, L Archambault, S Beddar
Journal of Physics: Conference Series 444 (1), 012013, 2013
692013
Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system
L Archambault, F Poenisch, N Sahoo, D Robertson, A Lee, MT Gillin, ...
Medical Physics 39 (3), 1239-1246, 2012
672012
Novel, full 3D scintillation dosimetry using a static plenoptic camera
M Goulet, M Rilling, L Gingras, S Beddar, L Beaulieu, L Archambault
Medical physics 41 (8Part1), 082101, 2014
662014
The robustness of dose distributions to displacement and migration of 125I permanent seed implants over a wide range of seed number, activity, and designs
L Beaulieu, L Archambault, S Aubin, E Oral, R Taschereau, J Pouliot
International Journal of Radiation Oncology* Biology* Physics 58 (4), 1298-1308, 2004
662004
Overview of Geant4 applications in medical physics
L Archambault, L Beaulieu, JF Carrier, F Castrovillari, S Chauvie, ...
2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No …, 2003
662003
Characterizing the response of miniature scintillation detectors when irradiated with proton beams
L Archambault, JC Polf, L Beaulieu, S Beddar
Physics in Medicine & Biology 53 (7), 1865, 2008
632008
The system can't perform the operation now. Try again later.
Articles 1–20