Comprehensive analysis of proton range uncertainties related to patient stopping-power-ratio estimation using the stoichiometric calibration M Yang, XR Zhu, PC Park, U Titt, R Mohan, G Virshup, JE Clayton, ... Physics in Medicine & Biology 57 (13), 4095, 2012 | 389 | 2012 |
Reducing metal artifacts in cone-beam CT images by preprocessing projection data Y Zhang, L Zhang, XR Zhu, AK Lee, M Chambers, L Dong International Journal of Radiation Oncology* Biology* Physics 67 (3), 924-932, 2007 | 326 | 2007 |
Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas MD Anderson Cancer Center, Proton Therapy Center, Houston MT Gillin, N Sahoo, M Bues, G Ciangaru, G Sawakuchi, F Poenisch, ... Medical physics 37 (1), 154-163, 2010 | 296 | 2010 |
Theoretical variance analysis of single-and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues M Yang, G Virshup, J Clayton, XR Zhu, R Mohan, L Dong Physics in Medicine & Biology 55 (5), 1343, 2010 | 289 | 2010 |
Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy L Zhang, AS Garden, J Lo, KK Ang, A Ahamad, WH Morrison, ... International Journal of Radiation Oncology* Biology* Physics 64 (5), 1559-1569, 2006 | 229 | 2006 |
Intensity-modulated proton beam therapy (IMPT) versus intensity-modulated photon therapy (IMRT) for patients with oropharynx cancer–a case matched analysis P Blanchard, AS Garden, GB Gunn, DI Rosenthal, WH Morrison, ... Radiotherapy and Oncology 120 (1), 48-55, 2016 | 226 | 2016 |
4D Proton treatment planning strategy for mobile lung tumors Y Kang, X Zhang, JY Chang, H Wang, X Wei, Z Liao, R Komaki, JD Cox, ... International Journal of Radiation Oncology* Biology* Physics 67 (3), 906-914, 2007 | 213 | 2007 |
The MD Anderson proton therapy system A Smith, M Gillin, M Bues, XR Zhu, K Suzuki, R Mohan, S Woo, A Lee, ... Medical physics 36 (9Part1), 4068-4083, 2009 | 212 | 2009 |
Consensus guidelines for implementing pencil-beam scanning proton therapy for thoracic malignancies on behalf of the PTCOG thoracic and lymphoma subcommittee JY Chang, X Zhang, A Knopf, H Li, S Mori, L Dong, HM Lu, W Liu, ... International Journal of Radiation Oncology* Biology* Physics 99 (1), 41-50, 2017 | 207 | 2017 |
Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator XR Zhu, PA Jursinic, DF Grimm, F Lopez, JJ Rownd, MT Gillin Medical Physics 29 (8), 1687-1692, 2002 | 197 | 2002 |
Initial experience of FDG-PET/CT guided IMRT of head-and-neck carcinoma D Wang, CJ Schultz, PA Jursinic, M Bialkowski, XR Zhu, WD Brown, ... International Journal of Radiation Oncology* Biology* Physics 65 (1), 143-151, 2006 | 196 | 2006 |
Effectiveness of robust optimization in intensity‐modulated proton therapy planning for head and neck cancers W Liu, SJ Frank, X Li, Y Li, PC Park, L Dong, X Ronald Zhu, R Mohan Medical physics 40 (5), 051711, 2013 | 189 | 2013 |
A beam-specific planning target volume (PTV) design for proton therapy to account for setup and range uncertainties PC Park, XR Zhu, AK Lee, N Sahoo, AD Melancon, L Zhang, L Dong International Journal of Radiation Oncology* Biology* Physics 82 (2), e329-e336, 2012 | 185 | 2012 |
Comparison of 2D radiographic images and 3D cone beam computed tomography for positioning head-and-neck radiotherapy patients H Li, XR Zhu, L Zhang, L Dong, S Tung, A Ahamad, KSC Chao, ... International Journal of Radiation Oncology* Biology* Physics 71 (3), 916-925, 2008 | 167 | 2008 |
Multifield optimization intensity modulated proton therapy for head and neck tumors: a translation to practice SJ Frank, JD Cox, M Gillin, R Mohan, AS Garden, DI Rosenthal, GB Gunn, ... International Journal of Radiation Oncology* Biology* Physics 89 (4), 846-853, 2014 | 166 | 2014 |
Four‐dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling J Lu, TM Guerrero, P Munro, A Jeung, PCM Chi, P Balter, XR Zhu, ... Medical physics 34 (9), 3520-3529, 2007 | 158 | 2007 |
Spatial mapping of the biologic effectiveness of scanned particle beams: towards biologically optimized particle therapy F Guan, L Bronk, U Titt, SH Lin, D Mirkovic, MD Kerr, XR Zhu, J Dinh, ... Scientific reports 5 (1), 9850, 2015 | 154 | 2015 |
Intensity-modulated proton therapy further reduces normal tissue exposure during definitive therapy for locally advanced distal esophageal tumors: a dosimetric study J Welsh, D Gomez, MB Palmer, BA Riley, AV Mayankkumar, R Komaki, ... International Journal of Radiation Oncology* Biology* Physics 81 (5), 1336-1342, 2011 | 150 | 2011 |
Clinical implementation of intensity modulated proton therapy for thoracic malignancies JY Chang, H Li, XR Zhu, Z Liao, L Zhao, A Liu, Y Li, N Sahoo, F Poenisch, ... International Journal of Radiation Oncology* Biology* Physics 90 (4), 809-818, 2014 | 146 | 2014 |
Consensus statement on proton therapy in early-stage and locally advanced non–small cell lung cancer JY Chang, SK Jabbour, D De Ruysscher, SE Schild, CB Simone II, ... International Journal of Radiation Oncology* Biology* Physics 95 (1), 505-516, 2016 | 133 | 2016 |