Quantitative susceptibility map reconstruction from MR phase data using bayesian regularization: validation and application to brain imaging L de Rochefort, T Liu, B Kressler, J Liu, P Spincemaille, V Lebon, J Wu, ... Magnetic Resonance in Medicine: An Official Journal of the International …, 2010 | 562 | 2010 |
Calculation of susceptibility through multiple orientation sampling (COSMOS): a method for conditioning the inverse problem from measured magnetic field map to susceptibility … T Liu, P Spincemaille, L De Rochefort, B Kressler, Y Wang Magnetic Resonance in Medicine: An Official Journal of the International …, 2009 | 396 | 2009 |
Morphology enabled dipole inversion for quantitative susceptibility mapping using structural consistency between the magnitude image and the susceptibility map J Liu, T Liu, L de Rochefort, J Ledoux, I Khalidov, W Chen, AJ Tsiouris, ... Neuroimage 59 (3), 2560-2568, 2012 | 361 | 2012 |
A novel background field removal method for MRI using projection onto dipole fields T Liu, I Khalidov, L de Rochefort, P Spincemaille, J Liu, AJ Tsiouris, ... NMR in Biomedicine 24 (9), 1129-1136, 2011 | 322 | 2011 |
Morphology enabled dipole inversion (MEDI) from a single‐angle acquisition: comparison with COSMOS in human brain imaging T Liu, J Liu, L De Rochefort, P Spincemaille, I Khalidov, JR Ledoux, ... Magnetic resonance in medicine 66 (3), 777-783, 2011 | 283 | 2011 |
Nonlinear formulation of the magnetic field to source relationship for robust quantitative susceptibility mapping T Liu, C Wisnieff, M Lou, W Chen, P Spincemaille, Y Wang Magnetic resonance in medicine 69 (2), 467-476, 2013 | 244 | 2013 |
Tool for accurate quantification in molecular MRI Y Wang, L De Rochefort, B Kressler, T Liu, P Spincemaille US Patent 8,781,197, 2014 | 236 | 2014 |
Nonlinear regularization for per voxel estimation of magnetic susceptibility distributions from MRI field maps B Kressler, L De Rochefort, T Liu, P Spincemaille, Q Jiang, Y Wang IEEE transactions on medical imaging 29 (2), 273-281, 2009 | 210 | 2009 |
Cerebral microbleeds: burden assessment by using quantitative susceptibility mapping T Liu, K Surapaneni, M Lou, L Cheng, P Spincemaille, Y Wang Radiology 262 (1), 269-278, 2012 | 167 | 2012 |
Background field removal by solving the Laplacian boundary value problem D Zhou, T Liu, P Spincemaille, Y Wang NMR in Biomedicine 27 (3), 312-319, 2014 | 149 | 2014 |
Respiratory and cardiac self‐gated free‐breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition J Liu, P Spincemaille, NCF Codella, TD Nguyen, MR Prince, Y Wang Magnetic resonance in medicine 63 (5), 1230-1237, 2010 | 125 | 2010 |
Clinical quantitative susceptibility mapping (QSM): Biometal imaging and its emerging roles in patient care Y Wang, P Spincemaille, Z Liu, A Dimov, K Deh, J Li, Y Zhang, Y Yao, ... Journal of magnetic resonance imaging 46 (4), 951-971, 2017 | 113 | 2017 |
Flow compensated quantitative susceptibility mapping for venous oxygenation imaging B Xu, T Liu, P Spincemaille, M Prince, Y Wang Magnetic resonance in medicine 72 (2), 438-445, 2014 | 105 | 2014 |
Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI T Liu, W Xu, P Spincemaille, AS Avestimehr, Y Wang IEEE transactions on medical imaging 31 (3), 816-824, 2012 | 102 | 2012 |
Quantitative mapping of cerebral metabolic rate of oxygen (CMRO2) using quantitative susceptibility mapping (QSM) J Zhang, T Liu, A Gupta, P Spincemaille, TD Nguyen, Y Wang Magnetic resonance in medicine 74 (4), 945-952, 2015 | 94 | 2015 |
Reducing the object orientation dependence of susceptibility effects in gradient echo MRI through quantitative susceptibility mapping J Li, S Chang, T Liu, Q Wang, D Cui, X Chen, M Jin, B Wang, M Pei, ... Magnetic resonance in medicine 68 (5), 1563-1569, 2012 | 90 | 2012 |
Preconditioned total field inversion (TFI) method for quantitative susceptibility mapping Z Liu, Y Kee, D Zhou, Y Wang, P Spincemaille Magnetic resonance in medicine 78 (1), 303-315, 2017 | 84 | 2017 |
In vivo quantification of contrast agent concentration using the induced magnetic field for time‐resolved arterial input function measurement with MRI L de Rochefort, T Nguyen, R Brown, P Spincemaille, G Choi, J Weinsaft, ... Medical physics 35 (12), 5328-5339, 2008 | 84 | 2008 |
Simultaneous phase unwrapping and removal of chemical shift (SPURS) using graph cuts: application in quantitative susceptibility mapping J Dong, T Liu, F Chen, D Zhou, A Dimov, A Raj, Q Cheng, P Spincemaille, ... IEEE transactions on medical imaging 34 (2), 531-540, 2014 | 70 | 2014 |
Magnetic susceptibility anisotropy: cylindrical symmetry from macroscopically ordered anisotropic molecules and accuracy of MRI measurements using few orientations C Wisnieff, T Liu, P Spincemaille, S Wang, D Zhou, Y Wang Neuroimage 70, 363-376, 2013 | 68 | 2013 |