Följ
Francois Therriault-Proulx
Francois Therriault-Proulx
Medscint inc.
Verifierad e-postadress på medscint.com - Startsida
Titel
Citeras av
Citeras av
År
On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry
F Therriault-Proulx, L Beaulieu, L Archambault, S Beddar
Physics in Medicine & Biology 58 (7), 2073, 2013
1142013
A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real‐time verification of 192Ir HDR brachytherapy
F Therriault‐Proulx, TM Briere, F Mourtada, S Aubin, S Beddar, ...
Medical physics 38 (5), 2542-2551, 2011
1112011
Impact of interseed attenuation and tissue composition for permanent prostate implants
JF Carrier, L Beaulieu, F Therriault‐Proulx, R Roy
Medical physics 33 (3), 595-604, 2006
992006
Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors
DM Klein, RC Tailor, L Archambault, L Wang, F Therriault‐Proulx, ...
Medical physics 37 (10), 5541-5549, 2010
842010
A mathematical formalism for hyperspectral, multipoint plastic scintillation detectors
L Archambault, F Therriault-Proulx, S Beddar, L Beaulieu
Physics in Medicine & Biology 57 (21), 7133, 2012
612012
Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range
F Lessard, L Archambault, M Plamondon, P Després, F Therriault‐Proulx, ...
Medical physics 39 (9), 5308-5316, 2012
592012
Development of a novel multi-point plastic scintillation detector with a single optical transmission line for radiation dose measurement
F Therriault-Proulx, L Archambault, L Beaulieu, S Beddar
Physics in Medicine & Biology 57 (21), 7147, 2012
572012
On the use of a single‐fiber multipoint plastic scintillation detector for 192Ir high‐dose‐rate brachytherapy
F Therriault‐Proulx, S Beddar, L Beaulieu
Medical physics 40 (6Part1), 062101, 2013
542013
Removing the stem effect when performing Ir‐192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: A relevant and necessary step
F Therriault‐Proulx, S Beddar, TM Briere, L Archambault, L Beaulieu
Medical physics 38 (4), 2176-2179, 2011
492011
Effect of magnetic field strength on plastic scintillation detector response
F Therriault-Proulx, Z Wen, G Ibbott, S Beddar
Radiation measurements 116, 10-13, 2018
302018
A real‐time method to simultaneously measure linear energy transfer and dose for proton therapy using organic scintillators
F Alsanea, F Therriault‐Proulx, G Sawakuchi, S Beddar
Medical physics 45 (4), 1782-1789, 2018
272018
A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector
F Therriault-Proulx, L Wootton, S Beddar
Physics in Medicine & Biology 60 (20), 7927, 2015
232015
Comparative optic and dosimetric characterization of the HYPERSCINT scintillation dosimetry research platform for multipoint applications
E Jean, F Therriault-Proulx, L Beaulieu
Physics in Medicine & Biology 66 (8), 085009, 2021
192021
Benchmarking a novel inorganic scintillation detector for applications in radiation therapy
M Alharbi, M Martyn, S O'Keeffe, F Therriault-Proulx, L Beaulieu, M Foley
Physica Medica 68, 124-131, 2019
192019
Characterization of a plastic scintillating detector for the small animal radiation research platform (SARRP)
CD Johnstone, F Therriault‐Proulx, L Beaulieu, M Bazalova‐Carter
Medical physics 46 (1), 394-404, 2019
172019
Validation of plastic scintillation detectors for applications in low-dose-rate brachytherapy
F Therriault-Proulx, L Beaulieu, S Beddar
Brachytherapy 16 (4), 903-909, 2017
172017
Characterization and practical applications of a novel plastic scintillator for online dosimetry for an ultrahigh dose rate (FLASH)
Y Poirier, J Xu, S Mossahebi, F Therriault‐Proulx, A Sawant
Medical Physics 49 (7), 4682-4692, 2022
162022
Characterization of an x‐ray tube‐based ultrahigh dose‐rate system for in vitro irradiations
DD Cecchi, F Therriault‐Proulx, S Lambert‐Girard, A Hart, A Macdonald, ...
Medical Physics 48 (11), 7399-7409, 2021
122021
Determining regions of interest for CCD camera‐based fiber optic luminescence dosimetry by examining signal‐to‐noise ratio
DM Klein, F Therriault‐Proulx, L Archambault, TM Briere, L Beaulieu, ...
Medical physics 38 (3), 1374-1377, 2011
122011
Quality assurance for Gamma Knife Perfexion using the Exradin W1 plastic scintillation detector and Lucy phantom
F Therriault-Proulx, R Pino, JN Yang, AS Beddar
Physics in Medicine & Biology 64 (22), 225007, 2019
112019
Systemet kan inte utföra åtgärden just nu. Försök igen senare.
Artiklar 1–20