Åsa Carlsson Tedgren
Åsa Carlsson Tedgren
Associate Professor, Linköping University
Verifierad e-postadress på liu.se
Titel
Citeras av
Citeras av
År
Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: current status and recommendations for clinical implementation
L Beaulieu, Å Carlsson Tedgren, JF Carrier, SD Davis, F Mourtada, ...
Medical physics 39 (10), 6208-6236, 2012
3402012
Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization
ÅK Carlsson, P Andreo, A Brahme
Physics in Medicine & Biology 42 (6), 1033, 1997
1001997
The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy
ÅK Carlsson, A Ahnesjö
Medical physics 27 (10), 2320-2332, 2000
712000
On the Monte Carlo simulation of small-field micro-diamond detectors for megavoltage photon dosimetry
P Andreo, H Palmans, M Marteinsdóttir, H Benmakhlouf, ...
Physics in Medicine & Biology 61 (1), L1, 2015
612015
Point kernels and superposition methods for scatter dose calculations in brachytherapy
ÅK Carlsson, A Ahnesjö
Physics in Medicine & Biology 45 (2), 357, 2000
562000
Lineal energy and radiation quality in radiation therapy: model calculations and comparison with experiment
L Lindborg, M Hultqvist, ÅC Tedgren, H Nikjoo
Physics in medicine & Biology 58 (10), 3089, 2013
552013
Accounting for high Z shields in brachytherapy using collapsed cone superposition for scatter dose calculation
ÅK Carlsson Tedgren, A Ahnesjö
Medical physics 30 (8), 2206-2217, 2003
502003
A generic high‐dose rate 192Ir brachytherapy source for evaluation of model‐based dose calculations beyond the TG‐43 formalism
F Ballester, Å Carlsson Tedgren, D Granero, A Haworth, F Mourtada, ...
Medical physics 42 (6Part1), 3048-3062, 2015
492015
Brachytherapy source characterization for improved dose calculations using primary and scatter dose separation
KR Russell, ÅK Carlsson Tedgren, A Ahnesjö
Medical physics 32 (9), 2739-2752, 2005
482005
Response of LiF: Mg, Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (< 1 MeV)
ÅC Tedgren, A Hedman, JE Grindborg, GA Carlsson
Medical physics 38 (10), 5539-5550, 2011
422011
Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy
Å Carlsson Tedgren, A Ahnesjö
Medical physics 35 (4), 1611-1618, 2008
392008
Evaluation of a lithium formate EPR dosimetry system for dose measurements around brachytherapy sources
L Antonovic, H Gustafsson, G Alm Carlsson, Å Carlsson Tedgren
Medical physics 36 (6Part1), 2236-2247, 2009
352009
Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy
E Adolfsson, G Alm Carlsson, JE Grindborg, H Gustafsson, E Lund, ...
Medical physics 37 (9), 4946-4959, 2010
342010
Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy
E Adolfsson, G Alm Carlsson, JE Grindborg, H Gustafsson, E Lund, ...
Medical physics 37 (9), 4946-4959, 2010
342010
On the biological basis for competing macroscopic dose descriptors for kilovoltage dosimetry: cellular dosimetry for brachytherapy and diagnostic radiology
RM Thomson, ÅC Tedgren, JF Williamson
Physics in Medicine & Biology 58 (4), 1123, 2013
312013
Influence of phantom material and dimensions on experimental dosimetry
ÅC Tedgren, GA Carlsson
Medical physics 36 (6Part1), 2228-2235, 2009
312009
Radiation dose measurements with alanine/agarose gel and thin alanine films around a 192Ir brachytherapy source, using ESR spectroscopy
S Olsson, ES Bergstrand, ÅK Carlsson, EO Hole, E Lund
Physics in Medicine & Biology 47 (8), 1333, 2002
312002
Impact of using linear optimization models in dose planning for HDR brachytherapy
Å Holm, T Larsson, Å Carlsson Tedgren
Medical physics 39 (2), 1021-1028, 2012
262012
Specification of absorbed dose to water using model-based dose calculation algorithms for treatment planning in brachytherapy
ÅC Tedgren, GA Carlsson
Physics in Medicine & Biology 58 (8), 2561, 2013
252013
Collapsed cone dose calculations for heterogeneous tissues in brachytherapy using primary and scatter separation source data
A Ahnesjö, B van Veelen, ÅC Tedgren
Computer methods and programs in biomedicine 139, 17-29, 2017
242017
Systemet kan inte utföra åtgärden just nu. Försök igen senare.
Artiklar 1–20