Följ
David M Higgins
David M Higgins
Clinical Science Lead, Europe-North, Philips
Verifierad e-postadress på philips.com - Startsida
Titel
Citeras av
Citeras av
År
Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
DR Messroghli, A Radjenovic, S Kozerke, DM Higgins, MU Sivananthan, ...
Magnetic Resonance in Medicine: An Official Journal of the International …, 2004
16012004
Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study
D Dabir, N Child, A Kalra, T Rogers, R Gebker, A Jabbour, S Plein, CY Yu, ...
Journal of Cardiovascular Magnetic Resonance 16 (1), 69, 2014
3732014
Human Myocardium: Single-Breath-hold MR T1 Mapping with High Spatial Resolution—Reproducibility Study1
DR Messroghli, S Plein, DM Higgins, K Walters, TR Jones, JP Ridgway, ...
Radiology 238 (3), 1004-1012, 2006
2982006
Native T1 in discrimination of acute and convalescent stages in patients with clinical diagnosis of myocarditis: a proposed diagnostic algorithm using CMR
R Hinojar, L Foote, E Arroyo Ucar, T Jackson, A Jabbour, CY Yu, ...
JACC: Cardiovascular Imaging 8 (1), 37-46, 2015
2252015
Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle
TN Bloomer, S Plein, A Radjenovic, DM Higgins, TR Jones, JP Ridgway, ...
Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2001
1332001
T1 measurement using a short acquisition period for quantitative cardiac applications
DM Higgins, JP Ridgway, A Radjenovic, UM Sivananthan, MA Smith
Medical physics 32 (6Part1), 1738-1746, 2005
752005
Comparison of fast acquisition strategies in whole‐heart four‐dimensional flow cardiac MR: Two‐center, 1.5 Tesla, phantom and in vivo validation study
P Garg, JJM Westenberg, PJ van den Boogaard, PP Swoboda, R Aziz, ...
Journal of Magnetic Resonance Imaging 47 (1), 272-281, 2018
692018
Dark-blood late gadolinium enhancement without additional magnetization preparation
RJ Holtackers, A Chiribiri, T Schneider, DM Higgins, RM Botnar
Journal of Cardiovascular Magnetic Resonance 19 (1), 64, 2016
662016
Aortic stiffness and interstitial myocardial fibrosis by native T1 are independently associated with left ventricular remodeling in patients with dilated cardiomyopathy
VO Puntmann, E Arroyo Ucar, R Hinojar Baydes, NB Ngah, YS Kuo, ...
Hypertension 64 (4), 762-768, 2014
662014
Review of T1 mapping methods: comparative effectiveness including reproducibility issues
DM Higgins, JC Moon
Current Cardiovascular Imaging Reports 7, 1-10, 2014
642014
Investigating the quantitative fidelity of prospectively undersampled chemical shift imaging in muscular dystrophy with compressed sensing and parallel imaging reconstruction
KG Hollingsworth, DM Higgins, M McCallum, L Ward, A Coombs, V Straub
Magnetic resonance in medicine 72 (6), 1610-1619, 2014
522014
Improving highly accelerated fat fraction measurements for clinical trials in muscular dystrophy: origin and quantitative effect of R2* changes
T Loughran, DM Higgins, M McCallum, A Coombs, V Straub, ...
Radiology 275 (2), 570-578, 2015
512015
Accelerating MR imaging liver steatosis measurement using combined compressed sensing and parallel imaging: a quantitative evaluation
LW Mann, DM Higgins, CN Peters, S Cassidy, KK Hodson, A Coombs, ...
Radiology 278 (1), 247-256, 2016
462016
Towards accurate and precise T 1 and extracellular volume mapping in the myocardium: a guide to current pitfalls and their solutions
D Cameron, VS Vassiliou, DM Higgins, PD Gatehouse
Magnetic Resonance Materials in Physics, Biology and Medicine 31, 143-163, 2018
372018
Susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2 star imaging for detection of intramyocardial hemorrhage following acute myocardial …
A Kidambi, JD Biglands, DM Higgins, DP Ripley, A Zaman, DA Broadbent, ...
Journal of Cardiovascular Magnetic Resonance 16, 1-11, 2014
302014
Sensitivity of quantitative myocardial dynamic contrast‐enhanced MRI to saturation pulse efficiency, noise and t1 measurement error: Comparison of nonlinearity …
DA Broadbent, JD Biglands, DP Ripley, DM Higgins, JP Greenwood, ...
Magnetic Resonance in Medicine 75 (3), 1290-1300, 2016
292016
T1 mapping performance and measurement repeatability: results from the multi-national T1 mapping standardization phantom program (T1MES)
G Captur, A Bhandari, R Brühl, B Ittermann, KE Keenan, Y Yang, ...
Journal of Cardiovascular Magnetic Resonance 22 (1), 31, 2020
272020
The effect of changes to MOLLI scheme on T1 mapping and extra cellular volume calculation in healthy volunteers with 3 tesla cardiovascular magnetic resonance imaging
AK McDiarmid, DA Broadbent, DM Higgins, PP Swoboda, A Kidambi, ...
Quantitative imaging in medicine and surgery 5 (4), 503, 2015
272015
Single bolus versus split dose gadolinium administration in extra-cellular volume calculation at 3 Tesla
AK McDiarmid, PP Swoboda, B Erhayiem, DP Ripley, A Kidambi, ...
Journal of Cardiovascular Magnetic Resonance 17, 1-6, 2015
252015
Color-encoded semiautomatic analysis of multi-slice first-pass magnetic resonance perfusion: comparison to tetrofosmin single photon emission computed tomography perfusion and …
H Thiele, S Plein, M Breeuwer, JP Ridgway, D Higgins, PJ Thorley, ...
The International Journal of Cardiovascular Imaging 20, 371-384, 2004
252004
Systemet kan inte utföra åtgärden just nu. Försök igen senare.
Artiklar 1–20