Följ
Robert Radwin
Titel
Citeras av
Citeras av
År
Repetitive trauma disorders: job evaluation and design
TJ Armstrong, RG Radwin, DJ Hansen, KW Kennedy
Human factors 28 (3), 325-336, 1986
3161986
Grip force vectors for varying handle diameters and hand sizes
CS Edgren, RG Radwin, CB Irwin
Human factors 46 (2), 244-251, 2004
2132004
A method for evaluating head-controlled computer input devices using Fitts' law
RG Radwin, GC Vanderheiden, ML Lin
Human factors 32 (4), 423-438, 1990
1861990
External finger forces in submaximal five-finger static pinch prehension
RG Radwin, S Oh, TR Jensen, JG Webster
Ergonomics 35 (3), 275-288, 1992
1781992
Power hand tool vibration effects on grip exertions
RG Radwin, TJ Armstrong, DB Chaffin
Ergonomics 30 (5), 833-855, 1987
1771987
A conductive polymer sensor for measuring external finger forces
TR Jensen, RG Radwin, JG Webster
Journal of biomechanics 24 (9), 851-858, 1991
1521991
Optimizing makespan and ergonomics in integrating collaborative robots into manufacturing processes
M Pearce, B Mutlu, J Shah, R Radwin
IEEE transactions on automation science and engineering 15 (4), 1772-1784, 2018
1502018
A silicon force sensor for robotics and medicine
DJ Beebe, AS Hsieh, DD Denton, RG Radwin
Sensors and Actuators A: Physical 50 (1-2), 55-65, 1995
1491995
Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction
KP Cohen, WM Ladd, DM Beams, WS Sheers, RG Radwin, WJ Tompkins, ...
IEEE Transactions on Biomedical Engineering 44 (7), 555-566, 1997
1421997
Ergonomics and the effects of vibration in hand-intensive work
TJ Armstrong, LJ Fine, RG Radwin, BS Silverstein
Scandinavian journal of work, environment & health, 286-289, 1987
1351987
A silicon-based tactile sensor for finger-mounted applications
DJ Beebe, DD Denton, RG Radwin, JG Webster
IEEE Transactions on Biomedical Engineering 45 (2), 151-159, 1998
1301998
Pistol grip power tool handle and trigger size effects on grip exertions and operator preference
S Oh, RG Radwin
Human factors 35 (3), 551-569, 1993
1301993
Muscle response to pneumatic hand tool torque reaction forces
RG Radwin, E VanBergeijk, TJ Armstrong
Ergonomics 32 (6), 655-673, 1989
1081989
A video-based system for acquiring biomechanical data synchronized with arbitrary events and activities
TY Yen, RG Radwin
IEEE transactions on Biomedical Engineering 42 (9), 944-948, 1995
1021995
Biomechanical aspects of work-related musculoskeletal disorders
RG Radwin, WS Marras, SA Lavender
Theoretical Issues in Ergonomics Science 2 (2), 153-217, 2001
1012001
An analytical method for characterizing repetitive motion and postural stress using spectral analysis
RG Radwin, ML Lin
Ergonomics 36 (4), 379-389, 1993
981993
Gain effects on performance using a head-controlled computer input device
ML Lin, RG Radwin, GC Vanderheiden
Ergonomics 35 (2), 159-175, 1992
961992
The accuracy of the Oculus Rift virtual reality head-mounted display during cervical spine mobility measurement
X Xu, KB Chen, JH Lin, RG Radwin
Journal of biomechanics 48 (4), 721-724, 2015
832015
Mental workload during brain–computer interface training
EA Felton, JC Williams, GC Vanderheiden, RG Radwin
Ergonomics 55 (5), 526-537, 2012
792012
A single metric for quantifying biomechanical stress in repetitive motions and exertions
ML Lin, RG Radwin, SH Snook
Ergonomics 40 (5), 543-558, 1997
791997
Systemet kan inte utföra åtgärden just nu. Försök igen senare.
Artiklar 1–20